Sign In | Join Free | My burrillandco.com
Home > Electrical Test Equipment >

Resistance 0 - 2MΩ Electrical Test Equipment Clamp Type Multimeter Calibrator

    Buy cheap Resistance 0 - 2MΩ Electrical Test Equipment Clamp Type Multimeter Calibrator from wholesalers
     
    Buy cheap Resistance 0 - 2MΩ Electrical Test Equipment Clamp Type Multimeter Calibrator from wholesalers
    • Buy cheap Resistance 0 - 2MΩ Electrical Test Equipment Clamp Type Multimeter Calibrator from wholesalers

    Resistance 0 - 2MΩ Electrical Test Equipment Clamp Type Multimeter Calibrator

    Ask Lasest Price
    Brand Name : GFUVE
    Model Number : GF6018A
    Certification : CE, ISO9001
    Price : Negotiable
    Payment Terms : T/T, Western Union, L/C, D/A, D/P, MoneyGram
    Supply Ability : 300 sets/month
    Delivery Time : 14 days
    • Product Details
    • Company Profile

    Resistance 0 - 2MΩ Electrical Test Equipment Clamp Type Multimeter Calibrator

    GF6018A Clamp Type Multimeter Calibrator Electrical Test Equipment


    The equipment of clamp type multimeter calibrator is compliance with national verification regulation: JJG124-2005 “Ammeter, voltmeter, power meter and resistance meter verification rules” and related national standards. 0.05 single-phase AC/DC standard source, can verify magnitude 0.2 and the following AC/DC voltmeter, ammeter, frequency meter, resistance meter. The source signals by using DSP and 16-bit high-speed analog-to-digital converters of controllable sine wave, the distorted wave signal source.The equipment comes with RS-232 interface, can be connected with PC to a semi-automatic verification system. It has precise interface and multi-functions including verification, storage and query.The equipment adopts color LCD screen, chart character display is clear, with high precision, stable and reliable, convenient operation and flexible characteristics.

    Calibration of Voltmeter, Ammeter & Wattmeter using Potentiometer The calibration is the process of checking the accuracy of the result by comparing it with the standard value. In other words, calibration checks the correctness of the instrument by comparing it with the reference standard.
    Calibration unit has a Voltmeter and an Ammeter, which can be Calibrated by Potentiometer. A Potentiometer is an instrument designed to measure an unknown voltage by comparing it with a known voltage. It has a high degree of accuracy.
    The best method of calibration is to measure the true value of current or voltage in the circuit and compare it with the value measured by the given ammeter or voltmeter. The true value of current or voltage in the circuit can be measured up to a fair grade of accuracy by using a potentiometer.

    Theory


    Calibration of multimeter in measurement technology and metrology is the comparison of measurement values delivered by a device under test with those of a calibration standard of known accuracy. Such a standard could be another measurement device of known accuracy, a device generating the quantity to be measured such as a voltage, or a physical artefact, such as a metre ruler.
    The outcome of the comparison can result in no significant error being noted on the device under test, a significant error being noted but no adjustment made, or an adjustment made to correct the error to an acceptable level. Strictly speaking, the term calibration means just the act of comparison, and does not include any subsequent adjustment.
    The calibration standard of multimeter and clamp meter is normally traceable to a national standard held by a National Metrological Institute.


    FEATURES


    • It can be semi-automatic or manual inspection of analog multi meter, clamp type current meter, all kinds of electric meter, (voltmeter, ammeter, frequency meters, resistance meter) basic error

    • The equipment can be generated with 2-31 harmonic wave, harmonic number, order, amplitude and harmonic phase of fundamental wave can be programmed

    • Power amplifier working frequency range is 40Hz-1KHZ, has a good linear. Current amplifier is constant current source; voltage amplifier is constant voltage source. Because of light weight, this device is more suitable for field use

    • With RS-232 interface, this device is controlled by PC through the PC software (optional), can be automatic or manual inspection, and the results are processing and management

    • Has a non-volatile memory, it can store 500 pieces of the raw data of tested meter, for access and upload

    PARAMETERS


    Electrical parameters  

    Power supplySingle phase AC 220V±10% or 110V±10%, 50/60HzAC

    AC Voltage output  

    range200mV, 400mV, 2000mV, 4000mV,
    20V, 100V, 200V, 500V, 1000V
    Range 20V-1000VAccuracy±(0.03%RD+0.02%FS)
    Stability≤0.01% FS /60s
    Range 200mV-4000mVAccuracy±(0.3%RD+0.2%FS)
    Stability≤0.04% FS /60s
    Load capacity20VA
    Waveform distortion≤0.3%
    Adjustable Range0-120% FS (1000V not included)
    Fineness5×10-5

    AC Current Output  

    Range2mA, 4mA, 20mA, 40mA, 0.2A, 0.5A, 2A, 5A, 10A, 20A
    Range 0.2A-20AAccuracy±(0.03%RD+0.02%FS)
    Stability≤0.01% FS /60s
    Range 2mA-40mAAccuracy±(0.3%RD+0.2%FS)
    Stability≤0.04% FS /60s
    Load capacity20VA
    Waveform distortion≤0.3%
    Adjustable Range0-120% FS
    Fineness5×10-5

    Frequency Output  

    Range45-65Hz
    Fineness0.001Hz
    Accuracy0.01Hz

    Harmonic Wave  

    Times2-31
    Extent0-20%
    Each harmonic phase fineness0.01·N (N is harmonic order)

    DC voltage output  

    Range200mV, 400mV, 2000mV, 4000mV,
    20V, 40V, 100V, 200V, 400V, 1000V
    Load capacity20W
    Adjustable range0-110% FS (1000V not included)
    Adjustable fineness5×10-5
    Stability≤0.01% FS /60s (peak-peak value)
    Accuracy±(0.03%RD+0.02%FS)
    Ripple wave≤1% FS

    DC current output  

    Range20uA, 40uA, 200uA, 400uA, 2mA, 4mA,
    20mA, 40mA, 0.2A, 1A, 2.5A, 5A, 10A, 20A
    Load capacity20W
    Adjustable Range0-110% FS (1000V not included)
    Adjustable Fineness5×10-5
    Stability≤0.01% FS /60s (peak-peak value)
    Accuracy±(0.06%RD+0.04%FS)
    Ripple wave≤1% FS

    Resistance box  

    Range0-200Ω, 200-400Ω, 0-2kΩ, 2kΩ-4kΩ, 0-20kΩ, 20kΩ-40kΩ,
    0-200kΩ, 200kΩ-400kΩ, 0-2MΩ, 2MΩ-4MΩ
    Fineness0.02%
    Range 0-2kΩ, 0-20kΩ, 0-200kΩ  
    Range 0-2kΩAdjustable Range0-100%FS
    Accuracy±(0.12%RD+0.08%FS)
    Range 0-200Ω,0-2MΩAdjustable Range0-100% FS
    Accuracy±(0.3%RD+0.2%FS)
    Range 2kΩ-4kΩ, 20kΩ-40kΩ, 200kΩ-400kΩ  
    Range 2kΩ-4kΩAdjustable Range5%-100%FS
    Accuracy±(0.12%RD+0.08%FS)
    Range 200-400Ω,
    2MΩ-4MΩ
    Adjustable Range5%-100% FS
    Accuracy±(0.3%RD+0.2%FS)

    Clamp meter range  

    200AAccuracy±0.2%
    600AAccuracy±0.5%
    1000AAccuracy±1%

    Dot frequency square wave output 

    Range1kHz, 5kHz, 10kHz, 50kHz, 100kHz, 200kHz, 1000kHz
    Square wave amplitude4.5V
    Setting accuracy5×10-5

    Mechanical parameters  

    Dimension (L×W×H) (mm)440x360x160
    Weight (kg)12

    Environmental conditions 

    Operating temperature20°C±10°C
    Relative humidity≤85%RH

    Photo


    Quality Resistance 0 - 2MΩ Electrical Test Equipment Clamp Type Multimeter Calibrator for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)